Knowledge Library

Topics & Articles

Sourced content on medical physics, imaging and radiation safety. The library keeps growing.

All Articles

Grouped by topic. Each article ships with its reference list.

Dose & Dosimetry

Patient dose, exposure parameters and the dose–image balance.

CT · Protocol Optimization

Multiphasic CT Scans: Why Phases Multiply Dose and When They Are Unnecessary

In computed tomography, each additional 'phase' (unenhanced, arterial, portal venous, delayed) is not a software post-processing filter; it is an entirely separate, full-dose radiation exposure. A 4-phase abdominal CT protocol quadruples cumulative patient dose. When are multiphasic examinations clinically indispensable, when do they represent unjustified radiation waste, and how can modern Dual-Energy CT eliminate redundant scans? Grounded in ACR Appropriateness Criteria and ICRP 102.

Image Formation & Quality

How the image forms, how its quality is measured and reconstructed.

Imaging · Informatics

What Is DICOM? JPEG, Window/Level, Header, PACS

DICOM is the common language of medical images: the standard that both stores a CT, MRI or ultrasound image and carries it between devices. It contains far more than a plain JPEG — full-dynamic-range pixel data plus a rich header. What is DICOM, why does it differ from JPEG, how does window/level change the image, what's in the header, and how does it work with PACS? We cover it all, with examples and page citations.

CT · Contrast & Dose

Iodine K-Edge Physics and CT Dose Optimization with Low kVp

Selecting 80 or 100 kVp instead of standard 120 kVp in computed tomography not only reduces radiation dose, but also nearly doubles the Hounsfield Unit (HU) attenuation of iodinated contrast media. The physical foundation behind this phenomenon is the 'Iodine K-edge (33.2 keV)' and photoelectric absorption. We explain how this mechanism works, how it cuts dose by 40–50%, and how to implement it clinically based on Bushberg and AAPM standards.

Artifacts

Appearances that aren't real: general and modality by modality.

General · Artifacts

What Are Image Artifacts? CT, MRI, Radiography & Ultrasound

Imaging systems do not copy anatomy exactly; they can add structures that aren't there or show real ones distorted. These false appearances are artifacts. Recognizing them is as important as interpreting the image — it prevents misdiagnosis and unnecessary repeat exposures (extra dose). With CT at its center, this is a reference guide to radiography, MRI and ultrasound artifacts, with physics, animations and page citations.

MRI · Artifacts

MRI Artifacts: Susceptibility, Chemical Shift, Wraparound

In MRI the image depends on the magnetic field and the radiofrequency signal being perfect; yet neither is. Metal, tissue–air boundaries, patient motion and signal processing each produce their own artifact. We cover MRI artifacts by Bushberg's classification — machine-, patient- and signal-processing-related — with physics, animations and page citations. This is the MRI deep-dive companion to our general artifacts guide.

Quality Control

Modality-based QC tests; what is measured, who performs it.

Fluoroscopy · Quality Control

Quality Control in Fluoroscopy: Dose Rate, AERC, Skin Dose

Fluoroscopy differs from other modalities in one respect: it is real-time and can run for minutes. That means doses to the patient's skin that can reach the threshold for deterministic effects (erythema, epilation). So fluoroscopy QC checks two things at once: that the dose rate stays within the legal limit and that the image is still diagnostic. From dose-rate limits to AERC, from phantom measurement to skin-dose tracking, with page citations.

Dose Management Systems

Automated collection, monitoring and optimization of patient dose data (IAEA HHS No. 49).

Fundamentals & General

Foundations of medical physics, protection and the general frame.

Fundamentals · Radiation Awareness

Effective Dose and mSv: How Much Radiation Is an X-ray or CT?

"How much radiation does this CT give me?" This is one of the most common questions from patients and clinicians alike. The common language of the answer is effective dose, measured in millisieverts (mSv). This article explains what effective dose is, why it does not by itself predict individual risk, the typical values per exam, and how they compare to natural background radiation — grounded in primary sources.

Current Literature

Recently published papers, read through the eyes of a medical physicist and set against local practice.

Current Literature · Radiation Protection

Why Is Routine Patient Shielding Ending in Radiology? (AEC & Scatter Physics)

For decades, draping a lead apron or gonadal shield over patients during X-ray and CT was the universal hallmark of radiation safety. Today, the AAPM, ACR, NCRP, and European societies (ESR/EFOMP) have formally recommended ending routine patient contact shielding. Patients are puzzled and clinicians are hesitant: How can a lead shield actually increase patient radiation dose? We break down the physics of Automatic Exposure Control (AEC) and internal scatter.